{"id":4969,"date":"2025-03-06T16:14:34","date_gmt":"2025-03-06T09:14:34","guid":{"rendered":"https:\/\/techconvina.com\/en\/?post_type=product&#038;p=4969"},"modified":"2025-03-06T16:14:34","modified_gmt":"2025-03-06T09:14:34","slug":"mechanical-booster","status":"publish","type":"product","link":"https:\/\/techconvina.com\/en\/product\/mechanical-booster\/","title":{"rendered":"Mechanical booster"},"content":{"rendered":"<h3 class=\"s_tt tm30\">Features and Benefits<\/h3>\n<div class=\"product_bottom_no_text_box tm10\"><strong><span class=\"no_bg\">01.<\/span>Excellent mechanical durability<\/strong><br \/>\nSuperior mechanical durability due to the non-contact operation between the screw and cylinder inside the pump<\/p>\n<p><strong><span class=\"no_bg\">02.<\/span>Operational stability<\/strong><br \/>\nExcellent operational stability and durability due to low-noise and low-vibration operation by precision machining and balancing<\/p>\n<p><strong><span class=\"no_bg\">03.<\/span>Various corrosion resistant coating<\/strong><br \/>\nVarious corrosion resistant coating<\/p>\n<p><strong><span class=\"no_bg\">04.<\/span>Excellent discharge capacity<\/strong><br \/>\nExcellent continuous discharge capacity and continuous operational performance even in harsh process environment<\/p>\n<p><strong><span class=\"no_bg\">05.<\/span>A variety of optional features<\/strong><br \/>\nPossible to apply flushing, purging and control system options according to the process characteristics<\/p>\n<p><strong><span class=\"no_bg\">06.<\/span>Echo friendly &amp; economical operation<\/strong><\/p>\n<ul class=\"basic\">\n<li>Economical and eco-friendly dry operation without using water and oil<\/li>\n<li>Superior efficiency compared to a vacuum pump single model (degree of vacuum and capacity in relation to power)<\/li>\n<\/ul>\n<p><strong><span class=\"no_bg\">07.<\/span>Flange-type motor with IEC standards<\/strong><br \/>\nAccurate and easy to assemble due to application of flange-type motor with IEC standards, and noise reduction realized through the optimal alignment assembly by machining tolerances<\/p>\n<p><strong><span class=\"no_bg\">08.<\/span>Easy maintenance<\/strong><br \/>\nEasy maintenance and cost savings due to simple structures by optimal design<\/p>\n<\/div>\n<h3 class=\"s_tt tm30\">Technical Data<\/h3>\n<table class=\"basic_table tm10\">\n<tbody>\n<tr>\n<th colspan=\"2\" rowspan=\"3\" width=\"10%\">Tape of construction<\/th>\n<th rowspan=\"2\" width=\"10%\">Theor.intake volume folw S<sup>th<\/sup>\u00a0in case of peration with 50Hz\/60Hz<\/th>\n<th rowspan=\"2\" width=\"10%\">Max.admissi-differen-tral pressure in case of motor riting<\/th>\n<th colspan=\"2\" width=\"20%\">oil Filling quantities for<\/th>\n<th rowspan=\"2\" width=\"10%\">Motor rating at 50Hz\/60Hz<\/th>\n<th rowspan=\"3\" width=\"10%\">Motor size<\/th>\n<th rowspan=\"2\" width=\"10%\">Speeds at 50Hz\/60Hz<\/th>\n<th colspan=\"2\" width=\"20%\">System voltages at<\/th>\n<\/tr>\n<tr>\n<th>GMa\/b<\/th>\n<th>GLa\/b<\/th>\n<th>50Hz<\/th>\n<th>60Hz<\/th>\n<\/tr>\n<tr>\n<th>[\u33a5\/h]<\/th>\n<th>[mbar]<\/th>\n<th>[litre]<\/th>\n<th>[litre]<\/th>\n<th>[kW]<\/th>\n<th>[1\/min]<\/th>\n<th>[v]<\/th>\n<th>[v]<\/th>\n<\/tr>\n<tr>\n<td>Gma\/GLa<\/td>\n<td>10.0HV<\/td>\n<td>180\/220<\/td>\n<td>130<\/td>\n<td>0.9<\/td>\n<td>0.7<\/td>\n<td>0.75\/0.85<\/td>\n<td>80<\/td>\n<td>3000\/3600<\/td>\n<td>230\/400<\/td>\n<td>440-480<\/td>\n<\/tr>\n<tr>\n<td>Gma\/GLa<\/td>\n<td>10.1HV<\/td>\n<td>250\/300<\/td>\n<td>140<\/td>\n<td>0.9<\/td>\n<td>0.7<\/td>\n<td>1.1\/1.32<\/td>\n<td>80<\/td>\n<td>3000\/3600<\/td>\n<td>230\/400<\/td>\n<td>440-480<\/td>\n<\/tr>\n<tr>\n<td>Gma\/GLa<\/td>\n<td>10.2HV<\/td>\n<td>365\/450<\/td>\n<td>130<\/td>\n<td>0.9<\/td>\n<td>0.7<\/td>\n<td>1.5\/1.8<\/td>\n<td>90s<\/td>\n<td>3000\/3600<\/td>\n<td>230\/400<\/td>\n<td>440-480<\/td>\n<\/tr>\n<tr>\n<td>Gma\/GLa<\/td>\n<td>11.3HV<\/td>\n<td>500\/600<\/td>\n<td>140<\/td>\n<td>1.1<\/td>\n<td>0.8<\/td>\n<td>2.2\/2.6<\/td>\n<td>90L<\/td>\n<td>3000\/3600<\/td>\n<td>230\/400<\/td>\n<td>440-480<\/td>\n<\/tr>\n<tr>\n<td>Gma\/GLa<\/td>\n<td>11.4HV<\/td>\n<td>750\/900<\/td>\n<td>130<\/td>\n<td>1.1<\/td>\n<td>0.8<\/td>\n<td>3\/3.6<\/td>\n<td>100L<\/td>\n<td>3000\/3600<\/td>\n<td>400\/690<\/td>\n<td>440-480<\/td>\n<\/tr>\n<tr>\n<td>Gma\/GLa<\/td>\n<td>12.5HV<\/td>\n<td>1000\/1200<\/td>\n<td>130<\/td>\n<td>1.5<\/td>\n<td>1.1<\/td>\n<td>4\/4.8<\/td>\n<td>100L<\/td>\n<td>3000\/3600<\/td>\n<td>400\/690<\/td>\n<td>440-480<\/td>\n<\/tr>\n<tr>\n<td>Gma\/GLa<\/td>\n<td>12.6HV<\/td>\n<td>1430\/1700<\/td>\n<td>130<\/td>\n<td>1.5<\/td>\n<td>1.1<\/td>\n<td>5.5\/6.3<\/td>\n<td>112L<\/td>\n<td>3000\/3600<\/td>\n<td>400\/690<\/td>\n<td>440-480<\/td>\n<\/tr>\n<tr>\n<td>Gma\/GLa<\/td>\n<td>16.f7 HV<\/td>\n<td>2000\/2400<\/td>\n<td>110<\/td>\n<td>2.5<\/td>\n<td>2.1<\/td>\n<td>7.5\/8.8<\/td>\n<td>132S<\/td>\n<td>3000\/3600<\/td>\n<td>400\/690<\/td>\n<td>440-480<\/td>\n<\/tr>\n<tr>\n<td>Gma\/GLa<\/td>\n<td>13.8 HV<\/td>\n<td>2900\/3450<\/td>\n<td>100<\/td>\n<td>2.5<\/td>\n<td>2.1<\/td>\n<td>11\/12.5<\/td>\n<td>160M<\/td>\n<td>3000\/3600<\/td>\n<td>400\/690<\/td>\n<td>440-480<\/td>\n<\/tr>\n<tr>\n<td>Gma\/GLa<\/td>\n<td>14.9 HV<\/td>\n<td>3900\/4700<\/td>\n<td>80<\/td>\n<td>7<\/td>\n<td>3.5<\/td>\n<td>11\/12.5<\/td>\n<td>160M<\/td>\n<td>3000\/3600<\/td>\n<td>400\/690<\/td>\n<td>440-480<\/td>\n<\/tr>\n<tr>\n<td>Gma\/GLa<\/td>\n<td>15.10 HV<\/td>\n<td>5600\/6700<\/td>\n<td>80<\/td>\n<td>12<\/td>\n<td>5.4<\/td>\n<td>15\/17<\/td>\n<td>160M<\/td>\n<td>3000\/3600<\/td>\n<td>400\/690<\/td>\n<td>440-480<\/td>\n<\/tr>\n<tr>\n<td>Gma\/GLa<\/td>\n<td>15.11 HV<\/td>\n<td>7500\/9000<\/td>\n<td>80<\/td>\n<td>12<\/td>\n<td>5.4<\/td>\n<td>18.5\/21.0<\/td>\n<td>160L<\/td>\n<td>3000\/3600<\/td>\n<td>400\/690<\/td>\n<td>440-480<\/td>\n<\/tr>\n<tr>\n<td>Gma\/GLa<\/td>\n<td>16.f13 HV<\/td>\n<td>8150\/9800<\/td>\n<td>75<\/td>\n<td>11<\/td>\n<td>7.6<\/td>\n<td>18.5\/21.0<\/td>\n<td>180M<\/td>\n<td>1500\/1800<\/td>\n<td>400\/690<\/td>\n<td>440-480<\/td>\n<\/tr>\n<tr>\n<td>Gma\/GLa<\/td>\n<td>16.13 HV<\/td>\n<td>9750\/11700<\/td>\n<td>75<\/td>\n<td>11<\/td>\n<td>7.6<\/td>\n<td>22\/25<\/td>\n<td>180L<\/td>\n<td>1500\/1800<\/td>\n<td>400\/690<\/td>\n<td>440-480<\/td>\n<\/tr>\n<tr>\n<td>Gma\/GLa<\/td>\n<td>17.15 HV<\/td>\n<td>16000\/18825<\/td>\n<td>60<\/td>\n<td>18.5<\/td>\n<td>&#8212;<\/td>\n<td>30\/36<\/td>\n<td>200L<\/td>\n<td>1500\/1800*<\/td>\n<td>400\/690<\/td>\n<td>440-480<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 class=\"s_tt tm30\">General Drawing<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-4971\" src=\"https:\/\/techconvina.com\/en\/wp-content\/uploads\/sites\/2\/2025\/03\/Mechanical-booster-General-Drawing.jpg\" alt=\"Mechanical booster General Drawing\" width=\"592\" height=\"170\" srcset=\"https:\/\/techconvina.com\/en\/wp-content\/uploads\/sites\/2\/2025\/03\/Mechanical-booster-General-Drawing.jpg 592w, https:\/\/techconvina.com\/en\/wp-content\/uploads\/sites\/2\/2025\/03\/Mechanical-booster-General-Drawing-300x86.jpg 300w, https:\/\/techconvina.com\/en\/wp-content\/uploads\/sites\/2\/2025\/03\/Mechanical-booster-General-Drawing-24x7.jpg 24w, https:\/\/techconvina.com\/en\/wp-content\/uploads\/sites\/2\/2025\/03\/Mechanical-booster-General-Drawing-36x10.jpg 36w, https:\/\/techconvina.com\/en\/wp-content\/uploads\/sites\/2\/2025\/03\/Mechanical-booster-General-Drawing-48x14.jpg 48w\" sizes=\"auto, (max-width: 592px) 100vw, 592px\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Mechanical booster is often referred to as roots blower, and it exhausts gas emission from the inlet to the outlet by compression by rotating 2peanut-shaped rotors inside the pump, while maintaining very small gap with body part. It helps to obtain very high exhaust speed and is very effective in the pressure range of 50~10-3mbr. Since mechanical booster pump is used in combination with a pump with low performance, it can greatly improve the problematic area with low exhaust speed of the pump with low performance and has an advantage of high efficiency in low vacuum area. In addition, its well balanced rotor in symmetric structure enables to maintain stability of large products and helps to realize high capacity performance with less driving force.<\/p>\n","protected":false},"featured_media":4970,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[152],"product_tag":[154,153],"class_list":{"0":"post-4969","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-vacuumize-vacuum-pump","7":"product_tag-vacuum-pump","8":"product_tag-vacuumize","10":"first","11":"instock","12":"shipping-taxable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/techconvina.com\/en\/wp-json\/wp\/v2\/product\/4969","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/techconvina.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/techconvina.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/techconvina.com\/en\/wp-json\/wp\/v2\/comments?post=4969"}],"version-history":[{"count":1,"href":"https:\/\/techconvina.com\/en\/wp-json\/wp\/v2\/product\/4969\/revisions"}],"predecessor-version":[{"id":4972,"href":"https:\/\/techconvina.com\/en\/wp-json\/wp\/v2\/product\/4969\/revisions\/4972"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/techconvina.com\/en\/wp-json\/wp\/v2\/media\/4970"}],"wp:attachment":[{"href":"https:\/\/techconvina.com\/en\/wp-json\/wp\/v2\/media?parent=4969"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/techconvina.com\/en\/wp-json\/wp\/v2\/product_brand?post=4969"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/techconvina.com\/en\/wp-json\/wp\/v2\/product_cat?post=4969"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/techconvina.com\/en\/wp-json\/wp\/v2\/product_tag?post=4969"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}