Description
FULFILLING SAFETY MEASURES.DUST COLLECTOR FOR EXPLOSIVE AND FLAMMABLE DUST.
- Designed to provide a high level of safety during the collection of potentially hazardous particles.
- Explosion pressure diffusion port(pressure from the explosion is discharged into the air to prevent damage to the equipment).
- Extinguisher port (in the unlikely event fire occurs in the equipment, extinguishing agent is dispensed).
- Check valve (prevent the reverse flow of blow force or fire to protect the worker).
Dust and powders that might cause explosions
– Magnesium
– Aluminum
– Aluminum light alloys
– Iron powder (non-oxidized)
– Epoxy Resin
– Cornstarch
– Titanium
– Toner
– Coal Dust
Other inflammable powders
Three conditions leading to dust explosions
1. Oxygen
2. Dust in a concentration higher than the explosion lower limit threshold
3. Minimum ignition energy
Dust explosions occur when the 3 conditions of “oxygen”, “Dust concentration higher than explosion threshold”, and “minimum ignition energy” are all present. If even just 1 of these conditions can be eliminated then dust explosions can be prevented. So the crucial point in preventing explosions is eliminating oxygen or sources of sparks.
Dust Explosion Prevention and Protection
Static electricity will make a spark and could be the ignition energy of a dust explosion. Anti-electrostatic woven plate filter employs metal thread woven into polyester technology and the filter has a strong and long-time antistatic effect and reduces the possibility of generating spark caused by static electricity.
Countermeasures against the problem of a dust explosion caused by static electricity are indispensable. The antistatic coating Conductive paint is effective in preventing static electricity and noise by painting on metal and plastic. The conductive paint prevents the spark inside the dust collector and dust explosion.
An explosion pressure diffusion port is designed to be the “weak” area of the dust collector body, an Explosion pressure diffusion port opens when predetermined pressures are reached inside the collector, allowing the excess pressure and flame front to exit to an Explosion pressure diffusion port. It is designed to minimize damage to the dust collector and prevent it from blowing up in the event of a deflagration, thereby reducing the safety hazard.
Kst and Pmax value
MODEL | KST VALUE | PMAX | |
---|---|---|---|
VNA-30SDN | 700 | 11.5 | |
VNA-45SDN | 700 | 11.5 | |
VNA-60DN | 300 | 11.0 |
The above Kst and Pmax value was covered and calculated based on “Japan Explosive pressure discharge device technical guidelines(Revised version)NllS-TR-No.38(2005) in incorporated agency industrial safety institute laws. The above figures are for standard equipment. Please evaluate your target dust for explosion potential (option: dust powder explosion evaluation service are available)
Dimension
Unit: mm
Specification
PARTICULAR | UNIT | VNA-30SDN | VNA-45SDN | VNA-60DN | |
---|---|---|---|---|---|
Power Supply | Volt | 220 | 220 | 220 | |
Frequency | Hz | 60 | 60 | 60 | |
Phase | 3P | 3P | 3P | ||
Output | kw/hp | 1.5/2 | 2.2/3 | 3.7/5 | |
Max Airflow | m³/min | 25 | 40 | 55 | |
Max. Static Pressure | kPa | 2.55 | 2.63 | 2.64 | |
Filter Area | m² | 9.0 | 13.5 | 18.0 | |
Suction Port Ø | mm | 150 | 200 | 200 | |
Dimension (WxDxH) | mm | 1020x1253x1754 | 1355x1328x1821 | 1546x1396x2055 | |
Weight | kg | 340 | 400 | 460 |